OTDeck

Battery/ESS · Modbus TCP

Victron Energy GX device - system values (com.victronenergy.system) Modbus register map

System-level summary values (grid, loads, PV, battery) published by the Modbus TCP server of a Victron GX device. 34 registers below, copied from the vendor's document; OTDeck adds them to a connection with Register map → Add from library.

Also covers
Cerbo GX, CCGX, Venus GX, Ekrano GX, Color Control GX
Link
Modbus TCP
Unit id default
100
Source
CCGX Modbus TCP register list (Field list sheet, com.victronenergy.system rows), 3.81 (Document versions sheet: Rev 54)
Addresses
The register list's 'Address' column is the Modbus register address sent on the wire (0-based). Address here = that value unchanged. Victron's Modbus TCP FAQ (https://www.victronenergy.com/live/ccgx:modbustcp_faq ) example sets 'the data address of the first request register to 3' for sheet address 3 and divides the reply by the sheet's scale factor 10.

Use unit ID 100 for com.victronenergy.system (ID 0 also works but many clients do not support it). Other devices (VE.Bus, solar chargers, battery monitors) have their own unit IDs; since Venus 2.60 they are assigned dynamically, see Settings > Integrations > Modbus TCP server > Available services. Enable the server under Settings > Services (Integrations on newer firmware) > Modbus TCP. Function codes 3, 4, 6 and 16 are supported; 3 and 4 are identical. SCALE: the register list's 'Scalefactor' column is a DIVISOR (value = raw / scalefactor); the scale here is its reciprocal. The list also offers 32-bit variants of many power values (registers 868-918); they are left out because the register list does not state the 32-bit word order.

Registers

Address: the 0-based protocol address sent on the wire. Ref: the same register in 1-based notation (40001 = holding 0). Scale: multiply the raw value by it.

NameTableAddressRefTypeOrderScaleUnit
Serial (System)/Serial: MAC address of the GX device as a 12-character string.Holding800–80540801string[6]
GX relay 1 stateWritable. /Relay/0/State: 0 = open, 1 = closed.Holding80640807uint16
GX relay 2 stateWritable. /Relay/1/State: 0 = open, 1 = closed.Holding80740808uint16
PV AC-coupled on output L1/Ac/PvOnOutput/L1/Power; sum of AC-coupled PV inverters on the output.Holding80840809uint16W
PV AC-coupled on output L2/Ac/PvOnOutput/L2/Power; sum of AC-coupled PV inverters on the output.Holding80940810uint16W
PV AC-coupled on output L3/Ac/PvOnOutput/L3/Power; sum of AC-coupled PV inverters on the output.Holding81040811uint16W
PV AC-coupled on input L1/Ac/PvOnGrid/L1/Power; sum of AC-coupled PV inverters on the input.Holding81140812uint16W
PV AC-coupled on input L2/Ac/PvOnGrid/L2/Power; sum of AC-coupled PV inverters on the input.Holding81240813uint16W
PV AC-coupled on input L3/Ac/PvOnGrid/L3/Power; sum of AC-coupled PV inverters on the input.Holding81340814uint16W
AC consumption L1/Ac/Consumption/L1/Power; power supplied by system to loads.Holding81740818uint16W
AC consumption L2/Ac/Consumption/L2/Power; power supplied by system to loads.Holding81840819uint16W
AC consumption L3/Ac/Consumption/L3/Power; power supplied by system to loads.Holding81940820uint16W
Grid L1/Ac/Grid/L1/Power; power supplied by grid to system.Holding82040821int16W
Grid L2/Ac/Grid/L2/Power; power supplied by grid to system.Holding82140822int16W
Grid L3/Ac/Grid/L3/Power; power supplied by grid to system.Holding82240823int16W
Genset L1/Ac/Genset/L1/Power.Holding82340824int16W
Genset L2/Ac/Genset/L2/Power.Holding82440825int16W
Genset L3/Ac/Genset/L3/Power.Holding82540826int16W
Active input source/Ac/ActiveIn/Source: 0 = unknown, 1 = grid, 2 = generator, 3 = shore power, 240 = not connected.Holding82640827int16
GX firmware major versionRender in hexadecimal to get the text version.Holding83440835uint16
GX firmware beta releaseZero for official releases.Holding83540836uint16
Battery voltage (System)/Dc/Battery/Voltage. Scalefactor 10 in the list (raw / 10).Holding84040841uint160.1V
Battery current (System)/Dc/Battery/Current; positive = charging, negative = discharging. Scalefactor 10.Holding84140842int160.1A
Battery power (System)/Dc/Battery/Power; positive = charging, negative = discharging.Holding84240843int16W
Battery state of charge (System)/Dc/Battery/Soc.Holding84340844uint16%
Battery state (System)/Dc/Battery/State: 0 = idle, 1 = charging, 2 = discharging.Holding84440845uint16
Battery consumed amphours (System)/Dc/Battery/ConsumedAmphours. Scalefactor -10 in the list (raw / -10, range 0 to -6553.6).Holding84540846uint16-0.1Ah
Battery time to go (System)/Dc/Battery/TimeToGo. Scalefactor 0.01 in the list (raw / 0.01). Special value 0 = charging.Holding84640847uint16100s
PV DC-coupled power/Dc/Pv/Power; sum of all solar chargers.Holding85040851uint16W
PV DC-coupled current/Dc/Pv/Current. Scalefactor 10.Holding85140852int160.1A
Charger power/Dc/Charger/Power.Holding85540856uint16W
DC system power/Dc/System/Power; power supplied by battery to system.Holding86040861int16W
VE.Bus charge current (System)/Dc/Vebus/Current; from the Multi to the DC system. Scalefactor 10.Holding86540866int160.1A
VE.Bus charge power (System)/Dc/Vebus/Power; positive = from the Multi to the DC system.Holding86640867int16W

Check the firmware and document version of your device against the source; registers differ between versions. Found a mistake? Write to support@otdeck.com. Product names are trademarks of their owners; OTDeck is not affiliated with them.