Changelog
Every OTDeck release, newest first. The macOS app updates itself; Windows and Linux builds tell you when a new version is out. Download the latest version.
0.12.1 2026-11-21
- M-Bus, the fifth protocol: OTDeck is now a wired M-Bus master (EN 13757-2 and -3) for heat, cooling, water, gas and electricity meters and heat cost allocators, through an M-Bus to Ethernet gateway in transparent mode or a USB or RS-232 level converter (2400 baud, even parity by default). Free: one connection, scans, the meter list, polling, decoded readings and trends.
- Find meters: a primary scan of addresses 0–250 that reports two meters on one address as a collision, and a secondary search that selects identification numbers digit by digit and goes deeper where meters answer together, so it finds every meter, also several on factory address 0. Add the ones you need, or add a meter by hand by identification number or primary address.
- Readings decoded per EN 13757-3: manufacturer, medium, version and status, and every record with its quantity, value scaled to the unit (energy always in kWh), storage number, tariff, subunit and function, with BCD, integer, real and variable-length data, dates, plain-text units and the VIF extension tables. Readings that take several telegrams are read to the end; error values are marked invalid; encrypted telegrams show their header.
- Polling of the meters you mark, every 30 s by default (1 s to 24 h), Read now per meter, any numeric record on the trend panel, and M-Bus meters in the command palette search.
- New primary address for a meter (Pro): sent to the meter selected by its identification number, so other meters on the old address keep theirs, and read back to check it took; an address another meter in the list is read by is refused. Behind production protection and in the write log.
- A reading after a selection is checked against the identification number, so an answer caused by another master on the same bus is refused instead of shown under the wrong meter.
- The simulator has an M-Bus gateway on 127.0.0.1:10001 with five meters, two of them sharing primary address 0 (Welcome → M-Bus meters).
- AI agents: read_meters reads the meters of an M-Bus connection with the decoded records, current or with the stored values; read-only, at most 20 meters per call (5 on production), calls on one bus take turns. The MCP server now has 18 tools.
- The M-Bus guide is on otdeck.com/docs/mbus.
0.11.2 2026-11-17
- Alarm test in the point checkout sheet (Pro): start it on a BACnet point that reports events, make the alarm happen (heat the sensor, use the command test or the head-end), and OTDeck watches Event_State and the notification. Pass, fail or timeout lands in the sheet, the CSV and the commissioning report, with the time of the alarm and of the return to normal, the notification class and priority, and a reason in words when it fails ("the state changed but no notification arrived: check the Recipient_List"). OTDeck never writes to the point during the test.
- BACnet properties other than Present_Value (Pro): a pencil next to High_Limit, Low_Limit, Deadband, Limit_Enable, Event_Enable, Time_Delay, Time_Delay_Normal, Notify_Type, Out_Of_Service, COV_Increment, Object_Name and Description, and on a Notification Class its Priority, Ack_Required and Recipient_List. Each write shows the value now on the device and after the write, goes through the write guard and the write log, and is read back.
- AI agents can ask for these property writes through write_nodes (a new property argument); each one opens the approval window with old and new value. Agents still cannot change a Recipient_List.
- BACnet add by address takes a port: 192.168.1.20:47809 adds a device on another UDP port of the connection's host. Discover still takes only devices on the connection's own address and port.
- Modbus UDP: the Modbus TCP frame over UDP, for devices and gateways that speak it. The connection dialog now explains RTU over TCP for serial gateways (transparent or raw mode, e.g. port 4001 on a Moxa NPort).
- otdeck-sim can put the simulated PLC behind a serial gateway (-modbus-rtu-tcp, -modbus-rtu-udp) or serve it over Modbus UDP (-modbus-udp), to try those connections without hardware.
- otdeck-mcp started by hand in a terminal says what it is and how to connect an agent, instead of waiting silently for MCP messages.
- User documentation is now on otdeck.com/docs.
- Fixes: the BACnet watch list keeps room for the value at the default window width (Mode and Time step aside below 820 px); an alarm test stopped while it is still reading the device no longer starts afterwards.
0.10.0 2026-11-12
- BACnet alarms in the top bar: with a BACnet connection open, an Alarms key counts the alarms waiting for an acknowledgement on every device (red with any, amber when active but all acknowledged, grey at 0). A background monitor reads them every 10 s (30 s on production, 60 s while the window is hidden), so you see alarms whichever screen is open.
- A system notification for every new alarm or fault, once per occurrence and with the same limits as watch rules; alarms a device already had are not announced. On by default, one switch per connection.
- Alarms tab: active alarms of one device or all devices, filtered by waiting for ack, active, priority group and name. Configured lists the objects that report events with limits, deadband, delay and the transitions reported, and marks a point that never reports the return to normal or names a missing notification class. Recipients shows every Notification Class and its Recipient_List in plain words.
- Receive notifications here (Pro): OTDeck adds itself to a Recipient_List and removes itself again, through the write guard and the write log. It remembers only the entries it added, reminds you to remove them before you leave the site and updates an entry at an old address in one step; a head-end's entries are never touched.
- Notifications are kept across restarts (bacnet-events.jsonl in the data folder, 2 MiB at most) and listed by device and transition. When an alarm is seen but its notification does not arrive within 5 minutes, OTDeck points at the firewall or NAT. Acknowledgements (Pro) record "OTDeck · <your user name>" as the source.
- From an alarm to the rest of OTDeck: open the object, make a watch rule from the alarm limits, add the point to a checkout sheet expecting normal, or trend it. BACnet checkout sheets get an Alarm column, and the commissioning report a BACnet alarms section (Pro).
- AI agents: list_events on a BACnet connection covers every device with priority, notification class, the transitions waiting and the notification history. Agents cannot change recipients; the MCP server keeps its 17 tools.
- Modbus RTU over TCP and RTU over UDP: RTU frames with their CRC to a serial gateway (Moxa NPort, USR, ADAM and others in RTU over TCP, transparent or raw mode). Reading, writing, polling, scans of unit ids 1–247 and the commissioning report work as on Modbus TCP.
- Windows: when BACnet devices do not answer or Discover finds nothing, OTDeck says where to allow it in the firewall (a closed Windows Security prompt blocks it).
- Simulator connections use an otdeck-sim that is already running at their address instead of starting the built-in one; BACnet add by address keeps the reason under the field when nothing is added; the checkout command test starts at the connection's write priority; the BACnet watch list no longer scrolls sideways.
- Free can remove OTDeck's own entries from a Recipient_List (adding stays Pro), so a lapsed licence never leaves an entry behind on a site; entries of other recipients are never removed.
- Security: built with Go 1.27.4 (net/http fix GO-2026-6859).
- Fixes: Export for team leaves out a fixed MQTT client id; an oversized OPC UA certificate import says "not a certificate file"; the minimum-version policy is kept in the keychain too; a flood of BACnet notifications no longer slows OTDeck down; Linux shows alarm text in notifications as plain text.
0.9.1 2026-11-11
- Watch lists filled from a point checkout come back after a restart: Watch all on a checkout sheet now saves the OPC UA nodes and BACnet objects it adds, the same as a Watch click.
- BACnet watch list on a narrow window: under 640 px the Mode and Time columns step aside (the time is in the value's tooltip), so values are no longer cut to "7…".
0.9.0 2026-11-11
- Point checkout: an I/O checkout sheet per connection. Open Checkout from a protocol view's toolbar or the command palette: MQTT topics, JSON fields and Sparkplug B metrics, Modbus registers, OPC UA nodes and BACnet objects, each with what you expect, the live value next to it and your result (pass, fail, skip or not checked) with the time, your name, the value you saw and a note.
- Fill the sheet in seconds: from the watch list (Modbus ranges, OPC UA and BACnet watch lists, trended and ruled values), from a snapshot, from a BACnet EDE file or from a CSV of name, address, expected and unit. Points already on the sheet merge instead of doubling.
- Expected values as you would write them: "21 ± 0.5 °C", "20..22", "on", "closed", or free text such as "matches the thermometer".
- Walk it by keyboard: Enter passes, F fails, S skips, Backspace clears, arrows move, on any keyboard layout; after each result the next open point is selected. Filter by all, not checked or failed; the progress line keeps count.
- Check all now: numbers, ranges and states are marked Pass (auto) or Fail (auto) from the live values. A stale, bad, uncertain, retained or missing value never passes, and your own results are never overwritten.
- Command test (Pro): write a test value to a writable point through the usual write guard, read it back within 5 s for pass or fail, then put it back: the old value, or on BACnet a relinquish at the same priority. One point at a time, never automatic.
- CSV export and a report section (Pro): the sheet exports to CSV with formula-safe cells, and the commissioning report gets a Point checkout section with the progress, every point and every command test. Free: one sheet of up to 25 points; Pro: up to 100 sheets of 2000 points.
- AI agents cannot read or change checkout results; the MCP server keeps its 17 tools.
- Linux: the dock and the app grid show the OTDeck icon instead of a grey gear. The icon is installed at every standard size from 16 to 512 px, and the window's app id matches the desktop entry.
- Windows and Linux: Help is the last menu (File, Edit, View, Help).
- Find devices: the subnet scan's progress ends at the total (254 of 254) instead of stopping a few hosts short.
0.8.2 2026-11-10
- Small screens: the title bar keeps every button in view. Narrower than 1000 px (a 1024×768 screen with the sidebar open), search, the protocols and Trends shrink to their icons, with the labels in the tooltips and for screen readers; Find devices, AI agents and the theme button are no longer cut off at the right.
0.8.1 2026-11-09
- Rule notifications lead with the condition: the title is the rule's name, the text says what happened ("Above 50 °C: 64 °C on Simulated PLC", "No update for 30 s on …"), with the same number format and unit as the Rules panel.
- Notifications turned off for OTDeck are visible: when macOS or Windows does not allow them, the Rules panel says so with a button to the system's notification settings, and notifications resume as soon as they are allowed, without a restart.
- BACnet rules pick their object from a list of watched and already read objects ("Supply temperature · analog-input:1"); a new rule takes the object's name and units, so the panel, the events, the notification and the commissioning report say "Supply temperature … 64 °C".
- Units in the snapshot comparison: a BACnet snapshot reads the units of analog objects itself, so the comparison shows "72 °C → 72.1 °C", also for objects never opened before.
- Command palette: MQTT topics with long JSON payloads keep their name in view; the value takes at most 40% of the row, the whole value in its tooltip.
- Schedule write confirmation: the changed lines are marked clearly in both themes.
- Commissioning report: "Last hour", "Last 8 hours" and "Today" end when the report is made, not when the dialog was opened. Rule events show the rule's unit.
- Windows: OTDeck.exe and otdeck-mcp.exe carry their product name, version, company and copyright in Properties › Details; otdeck-mcp.exe has the OTDeck icon.
- Small screens: on 1024×768 the window opens inside the screen's work area, and the welcome page's buttons wrap instead of being cut off.
0.8.0 2026-11-09
- Watch rules with notifications: Rules in the title bar watches any value OTDeck already receives (an MQTT topic, JSON field or Sparkplug B metric, a polled Modbus register, an OPC UA node, a BACnet present value) for above, below, outside or inside a band, equals, changes, no update for N seconds, or bad quality and fault, each with a deadband and an on-delay. A rule goes active, is acknowledged and returns to normal; Ack and Mute on every row, the transitions in an Events tab and in the commissioning report. System notifications on macOS, Windows and Linux, rate-limited. Free keeps 2 rules, Pro up to 200.
- Device snapshots: Snapshot in every protocol toolbar keeps every value OTDeck knows of a connection (Modbus ranges, the OPC UA watch list and an optional browse, every BACnet object's present value, flags and priority array, the last message of each MQTT topic) with the device identity and a note. A snapshot only reads, paced on production connections. Compare two snapshots, or one with the connection now: changed, added and removed values, before → after, grouped as the device groups them. Free keeps 3 snapshots; Pro keeps any number, exports the comparison to CSV and adds it to the commissioning report.
- Global tag search: ⌘K / Ctrl+K finds tags on every connection and saved profile (MQTT topics, Modbus registers by name or 40001-style address, OPC UA nodes, BACnet objects) with the value now; Enter opens the tag in its view, ⌘Enter adds it to the trend. Free.
- BACnet: Current_Command_Priority is property 431 (it was shown under 390).
- otdeck.com gets a BACnet object reference: what each object type is, its properties, priority array and COV behaviour, and field pitfalls, at https://otdeck.com/bacnet/objects
- Security review of the 0.8 work (findings 80 to 92, docs/security-audit-2026-11.md): snapshots from hostile devices stay small and always open, rule transitions are rate-limited so a chattering value cannot flush the event log, a BACnet rule is bound to one device, every CSV export neutralises full-width formula characters too, one connection cannot crowd the others out of the tag search, and two snapshots never overwrite each other.
0.7.0 2026-11-08
- BACnet schedules and calendars: the Schedule tab reads a Schedule object whole (present value, default, effective period, the week Monday to Sunday, the exceptions and the properties it writes) and a Calendar's date list. Edit the week in a grid (add, change and remove time-value entries, copy a day to other days), the exceptions (a date, a range, a week-and-day pattern or a calendar, with their own time values and priority) and the date list; values are typed by the schedule (active/inactive, state names, numbers, null). Write… shows the property now and after the write with the changed lines marked; Pro, behind the production guard, in the write log with the old and new schedule in full. The week goes day by day by array index, or whole when a device refuses that (remembered per device); a write cut off halfway says which days reached the device.
- EDE export: Export EDE… under the device list writes the BIG-EU Engineering Data Exchange files (layout 2.3) of one device or of every known device: the main file (keyname, device and object instance, name, type, description, default, min/max, settable, COV, limits, state-text reference, unit, notification class) and the state-text and unit-text files. Device text cannot turn into spreadsheet formulas, and existing files are never overwritten silently. Pro, like every export.
- Commissioning report (Pro): command palette → Commissioning report…, or Settings → Write log. Pick a period, the connections and the trend charts; OTDeck saves one HTML file to print or save as PDF with the connections and device identity, every write of the period (old → new value with units, who made it: you, or an AI agent with its name and reason, and the result), the write log's hash-chain check, acknowledged alarms, trend charts, the values at the end and a signature block. The file loads nothing from the web.
- Trends come back after a restart: the series on the trend panel are saved as you change them and return on the next start, OPC UA nodes and BACnet objects subscribed again on connect. On a normal quit OTDeck keeps the last hour of points (Free: 5 minutes) and shows them before a dashed line marked before restart.
- The write log keeps the value shown just before each Modbus, OPC UA and BACnet write, and the value written exactly as entered (65.5, not rounded).
- BACnet on real controllers: devices without ReadPropertyMultiple are read property by property, Object_List by array index, small APDUs with shorter pages, no Property_List with the standard set per type, proprietary objects and properties shown raw, names in Latin-1, UCS-2, DBCS code pages and JIS decoded, COV refused falls back to polling, ReadRange by time falls back to position, time stamps in the device's own zone, and the device's own error, reject and abort reasons instead of a bare timeout. The device panel lists this as Detected behaviour, and protocol services and object types are shown by name. The simulator can play a stubborn controller (otdeck-sim -bacnet-quirks).
- BACnet on slow devices: the status bar shows what is being read and how far, with Cancel; after a write the object panel rereads only present value, flags, out of service and priority array. Trend logs read each record once and never more than the log holds.
- Find devices shows the Who-Is result in its section header, in view. Welcome: Connect on a simulator connection starts the simulator first, and a failed connect is shown under its card and logged.
- Simulator: Boiler 7 gets an Occupancy schedule that commands a new Occupancy value, and a Holidays calendar.
- AI agents: read_nodes returns BACnet schedules and calendars whole (at most 5 per call, 1 on production connections); still 17 tools, schedules are read-only for agents.
- Security review of the 0.7 work (findings 67 to 79, docs/security-audit-2026-11.md): EDE cells are neutralised and side files never overwritten, device text cannot forge lines in the schedule confirmation, duplicate state texts no longer write the wrong value, a schedule write goes to the address you approved, and agent reads of schedules are bounded. Tests no longer touch the macOS keychain, and a run with a HOME that has no keychain keeps secrets in a private file instead of prompting.
0.6.0 2026-11-07
- BACnet/IP is the fourth protocol: add a BACnet device by address, or discover a subnet by broadcast; a BBMD for devices on other IP subnets; devices behind a BACnet router (MS/TP through the router). The device object, the object list grouped by type with names, every property of an object with units, status flags and out-of-service, and the 16-slot priority array with Relinquish per slot.
- BACnet watch list with COV subscriptions (renewed by OTDeck) and polling where a device refuses, each value with units and status flags; values go to the trend panel and recordings like OPC UA values.
- BACnet writes at a priority with the value shown as it will be sent (binary active/inactive, multi-state by state name), Relinquish (NULL), and priorities 1 to 8 refused unless the connection allows them. Pro, behind the production guard, in the write log as bacnet.write.
- BACnet trend logs (ReadRange by last N, position or time range, up to 10,000 records) as a table and a chart, CSV export (Pro); alarms from GetEventInformation with their transitions, time stamps and priorities, and AcknowledgeAlarm with the device's own time stamp (Pro, bacnet.ack in the write log).
- BACnet/SC node: connects to a hub over TLS 1.3 with your operational certificate (a failover hub too), discovers devices through the hub and does everything above over it; Pro. The connection dialog picks the certificate, key and CA files, makes a CSR with a new key for your CA to sign, or a test CA with a certificate for the simulator's hub; the status shows which hub serves and the Network Port error codes. The data link is OTDeck's own, pure Go, tested against bacnet-stack 1.7.0's hub.
- Find devices gets a BACnet Who-Is: one broadcast on an interface (or to one address) with an instance range; found devices prefill a connection.
- The simulator adds a BACnet/IP device, Boiler 7 (instance 2601) on 127.0.0.1:47809: supply and return temperature, pressure, a commandable setpoint, pump command and feedback, enable, mode, a trend log of the supply temperature and a HighTemperature alarm above 90 °C. It also runs a BACnet/SC hub on wss://127.0.0.1:47810 with a test CA and a second boiler (instance 2602) behind it; Welcome adds a connection to it with the certificates filled in.
- AI agents: browse, read_nodes, read_history, list_events, write_nodes and ack_alarm work on BACnet connections (object ids like device:2601/analog-input:1); still 17 tools. Writes go at the connection's write priority, null relinquishes.
- Hostile BACnet devices: every list, string and value is bounded; oversize object lists, endless segmented answers, malformed answers and endless alarm and trend-log pages are cut short (docs/security-audit-2026-11.md, BACnet section). The client library is otfabric/go-bacnet 0.6.0 (MIT).
- Security review of the BACnet work (findings 52 to 66, docs/security-audit-2026-11.md): a connection with an address keeps to that address (the shared UDP socket no longer lets one profile reach every device it has seen, which could sidestep a team policy or a production role), a profile edit no longer races the poller, otdeck-mcp connects to a BACnet/SC hub as a node of its own so it stops knocking the app's connection off the hub, hub redirects are never followed, the approval window shows the whole value, the priority per object, the device and its address and refuses a write that changed meanwhile, notifications are kept per device and shown with their device, certificate files are read with a size cap, the CA field must hold a CA, the simulator's test PKI lives in a private per-user directory, and a new CSR never overwrites the key of one already sent.
0.5.0 2026-11-06
- OPC UA aggregated history: History… gets Raw and Aggregate. Aggregate asks the server for one value per interval (10 s to 1 h, or the whole range): Average, Minimum, Maximum, Count, Interpolative, Start, End, Range, Total or TimeAverage, with the Calculated, Interpolated and Partial status shown. Free, like raw history; CSV export is Pro. The simulator computes them too.
- Sparkplug B edge node: when its MQTT session drops, it reconnects by itself as a new session (the next bdSeq, NBIRTH and DBIRTHs again, metric values kept), and shows Reconnecting with the attempt meanwhile. It also follows the connection while it runs: made read-only or production, it stops.
- AI agents can ask to call OPC UA methods (call_method) and to acknowledge or confirm alarms (ack_alarm), on connections set to Read and write for agents (Pro). The approval window shows the method, its object and every argument as it will be sent, or the alarm's source, message, severity and state; nothing happens until you allow it, production needs the name typed, and each one is in the write log with the agent and its reason. 17 tools.
- The Call dialog shows the arguments as they will be sent (0x10 as 16) before the call; numbers with a leading zero, underscores or 0b/0o prefixes are refused.
- Security audit of 0.3 and 0.4 (findings 28 to 40, docs/security-audit-2026-11.md): the edge node keeps to the connection's current guard, the events panel no longer copies every event twice a second, rebirth floods from the broker are coalesced, agent writes refuse negative scales, CSV export neutralises more formula starts, and two compression libraries are updated.
- Security review of the new agent tools (findings 41 to 51): the approval window shows every argument in full (agents' calls with very large arguments are refused), the method must belong to the object, the arguments sent are the ones you saw, and an alarm is looked up again when you allow: if it changed meanwhile, nothing is acknowledged. A stopped edge node now leaves its NDEATH, and Stop no longer waits for a reconnect attempt.
- The simulator's register map shows temperatures and the setpoint in °C (scale 0.1) and pressure, flow and vibration with their units. New screenshots on otdeck.com.
0.4.0 2026-11-06
- OPC UA method calls: Call… on a method (or Methods… on an object) reads its input and output arguments, shows a form with each argument's name, data type and description, converts the values (built-in types and arrays of them) and shows the status name and code, the result of each argument and the outputs. A call is a write: Pro, refused on read-only connections, the name typed on production, in the write log.
- OPC UA history: History… on a variable the server historizes reads raw values for the last 15 minutes, hour, 24 hours or a custom range, up to 10,000 values, following the server's continuation points and releasing them on Cancel. Values in a table and a chart; reading is free, CSV export is Pro.
- OPC UA events and alarms: an Events tab next to the watch list subscribes to the Server object (or any object), lists events live with severity as text and icon, filters by severity and source, and shows every field on click. Active alarms come in through ConditionRefresh and can be acknowledged or confirmed with a comment (Pro, with the same guard and write log as a write).
- MQTT publish templates: save named publishes per connection (topic, payload, format, QoS, retain, content type) and use them again. Payload variables {{now}}, {{ts}}, {{uuid}}, {{counter}} and {{random:min:max}}; repeat every 100 ms or more, a number of times or until stopped. Free.
- Sparkplug B edge node simulator (Pro): define a group, an edge node, devices and metrics with constant, random walk, sine or counter values, and run it on an MQTT connection: NBIRTH with bdSeq and Node Control/Rebirth, DBIRTH, NDATA/DDATA by alias, NDEATH as the will, rebirth on request and NCMD/DCMD writes shown as they arrive.
- Simulator: the OPC UA server gets methods (Press.SetSetpoint, Press.Reset), two hours of Temperature history and a HighTemperature alarm that turns active and inactive every minute and can be acknowledged.
- AI agents: read_history and list_events, read-only, within the same production limits; 15 tools.
0.3.0 2026-11-06
- Modbus register ranges get an optional scale, unit and description. The register browser, trends and AI agents see the scaled value (230.5 V instead of 2305), the raw value stays visible; writes take the engineering value and refuse one that is not a whole raw number.
- Import a register map from CSV, TSV or semicolon-separated files: columns found by name (name, table, address, data type, count, byte order, scale, unit, description), 0-based, 1-based or 40001-style addresses detected or chosen, a preview with the problem of each row, then add or replace. Export writes the same format back.
- Device library: register maps of 9 devices copied from the vendors' documents (Eastron SDM120, SDM120CT, SDM230, SDM630, Carlo Gavazzi EM540, Schneider Electric iEM3255, ABB B23/B24, SunSpec inverter model 103, Victron GX), each with its source, link defaults and unit id.
- Modbus scanner: find the unit ids that answer on a line or gateway (free), and the readable registers of a device (Pro), with read requests only. Found unit ids can be used in one click, found registers added as ranges; production connections need the name typed and are scanned at most 10 requests a second.
- AI agents: read_registers and list_connections report a range's scale, unit and description; write_registers takes a scale, and the approval window shows the exact raw registers.
- Import, export and the device library are free on every plan.
0.2.2 2026-11-05
- AI agents show under their product names: Claude Code, Claude Desktop, Cursor, Codex, VS Code and others, instead of claude-code or cursor-vscode, in the approval window, the write log and the agent status.
- Welcome: Connect to the simulated MQTT broker, Modbus PLC or OPC UA server starts the simulator first when it is not running, instead of failing to connect.
- Export for team: a new option, AI agents never ask to write to the team's devices (noAgentWrites), so the policy no longer needs editing by hand.
0.2.1 2026-11-05
- A system notification when an AI agent asks to write while OTDeck is minimised or behind another app; clicking it opens the request. macOS asks once whether OTDeck may send notifications.
- Signed releases: SHA256SUMS now comes with SHA256SUMS.sig, an Ed25519 signature by OTDeck's release key, which is not stored with the files. How to check it with OpenSSL: otdeck.com/download, Check the signature.
0.2.0 2026-11-04
- AI agents can ask to write (Pro and Team): otdeck-mcp gets write_registers, write_nodes and publish_message. The MCP server never writes itself; each request opens a window in OTDeck with the values now and the new ones exactly as they will be written, and the agent's reason. Nothing is written until you click Allow.
- Production connections also need the connection name typed; Deny, Escape or no answer in 60 seconds is a denial. Requests come one at a time, Allow wakes up a second after a window appears, and a connection edited while a request waits drops it.
- New AI agents setting in Edit connection: Hidden, Read (default) or Read and write. Read-only connections refuse agent writes; a robot mark in the sidebar shows where agents may ask.
- Team policy noAgentWrites: AI agents may read but never ask to write to the team's devices. Every member needs OTDeck 0.2 before the key is added to the team file.
- Write log: agent writes carry the agent's name and reason; denied and unanswered requests are logged too.
- Limits per agent call: 100 Modbus values, 25 OPC UA nodes or one MQTT message up to 64 KB, one request per second per connection.
0.1.0 2026-11-04
- First beta: one desktop workbench for MQTT, Modbus TCP/RTU and OPC UA on Windows, macOS and Linux (amd64 and arm64).
- MQTT 5 and 3.1.1 over TCP, TLS (CA and client certificates), WebSocket and WebSocket + TLS: live topic tree with counts and rates, payloads as JSON, text or hex, MQTT 5 properties, retained and QoS, publish, subscriptions, automatic reconnect.
- Sparkplug B: births, deaths and data decoded, metric names resolved from births, metrics on the trend panel.
- Modbus TCP and RTU: coils, discrete inputs, holding and input registers; bool, int16, uint16, hex, int32, uint32, int64, uint64, float32, float64 and string with byte and word order (ABCD, CDAB, BADC, DCBA); polling with backoff on failing ranges; exceptions in plain words; writes with functions 05, 06, 15 and 16 (Pro).
- OPC UA: endpoint discovery, None and Basic256Sha256 with Sign or SignAndEncrypt, anonymous or username login, a client certificate and a trust list with a first-connect prompt; address-space tree, attributes, watch list of monitored items, writes (Pro).
- Trends from all three protocols on one panel: up to 32 series of 36 000 points, 1 minute to 1 hour, one axis or lanes. Recording, replay at 0.25× to 100× and CSV/Parquet export (Pro).
- Built-in simulator: an MQTT broker with factory telemetry and Sparkplug B, a Modbus TCP PLC and an OPC UA server on 127.0.0.1, started from the Welcome screen.
- otdeck-mcp, an MCP server for AI agents with 10 read-only tools for connections, MQTT topics, Modbus registers, OPC UA nodes, trends and recordings; one-click setup for Claude Desktop, Claude Code, Cursor, Codex and VS Code.
- Production safety: lab, staging and production roles; production connections start read-only and every write needs the connection name typed, checked in the backend.
- Free forever with one open connection; Pro ($99 once, a year of updates) and Team ($149 per seat a year) keys with online or offline activation; time-limited beta licences for testers.
- Packages: notarized macOS DMG (universal) with automatic updates, Windows installers for x64 and Arm, Linux .deb, .rpm and tar.gz.